Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Semin Thorac Cardiovasc Surg ; 34(2): 512-516, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34089830

RESUMO

The edge-to-edge mitral valve repair technique, invented by Alfieri and colleagues, introduced valve repair as a treatment option for patients with complex diseases where standard annuloplasty and related repair techniques are insufficient, due to annular calcification and patient frailty. We retrospectively evaluated the results of a transaortic edge-to-edge mitral valve repair (Alfieri stitch) in high-risk patients who were undergoing aortic valve replacement. From February, 2012 to December, 2017, 43 patients underwent transaortic edge-to-edge mitral valve repair with concomitant aortic valve replacement at a single institution. Preoperative and postoperative echocardiograms were compared. Home telephone follow up was conducted and postoperative morbidity was examined, including the need for reoperation, stroke and cardiac arrhythmia. 30-day and long-term survival rates were also determined. Mitral regurgitation (MR) was graded semi-quantitatively as 0 (trace and/or none), mild (1), moderate (2) or moderate to severe (3-4). The patients were 74 ± 7.8 years old. 65% of the patients were male. Mean cardiopulmonary bypass time was 115 ± 37 minutes and mean cross-clamp time was 71 ± 23 minutes. There was a significant improvement in preoperative vs postoperative median MR grade (2 (IQR 2-3) vs 0 (IQR 0-1); P = 0.05). Follow-up transthoracic echocardiograms in 29 patients obtained at a median of 9 months' (range 3 - 19 months') and in 16 patients at a median of 34 months' postoperatively (range 21 - 53 months') showed mild (1 (IQR 1-2)) grade of mitral regurgitation. 30-day survival was 98%. Long term survival at 12 and 24 months' were 88% and 81% respectively. Mitral valve reoperation was conducted in 1 patient (2%), who was suffering of endocarditis. Stroke occurred in 2 patients (7%). Cardiac arrhythmia was observed in 15 patients (35%). 8 patients (19%) suffered from atrial fibrillation and 7 patients (16%) displayed atrioventricular blockage. 10 patients (23%) could be treated conservatively and 5 patients (12%) needed implantation of a pacemaker. Transaortic edge-to-edge mitral valve repair can be safely performed during aortic valve replacement in high-risk patients and improves even long-term MR grade. Postoperative cardiac arrhythmia occurs frequently. 66% of them could be treated successfully by conservative procedures.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
2.
Int J Artif Organs ; 43(6): 385-392, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31849254

RESUMO

BACKGROUND: Heart failure is one of the most expensive chronic diseases, as it leads to considerable expenses due to increasing hospitalisation rates. In addition to the implications of the demographic transition and the lack of available organs for transplantation, a major challenge in this context is that conservative treatment options are limited. This has led to the research and development of mechanical circulatory assist systems. Telemonitoring is anticipated to be an effective tool in outpatient management, which may be a key to improved outcomes of left ventricular assist devices therapy. In patients with chronic cardiac diseases, telemedicine is already used and has been shown to reduce premature mortality. This study aims to provide insights into the left ventricular assist device-specific requirements for telemonitoring and infrastructural translation from caregivers' and patients' points of view. METHOD: A qualitative investigation based on guided interview and focus group techniques was conducted at two German heart centres. The study included 15 patients and 7 caregivers (4 cardiac surgeons, 3 ventricular assist device coordinators). Qualitative content analysis was used for data analysis. The categories for analysis were (1) benefits for patients, (2) benefits for hospitals and the healthcare system, (3) acceptance and causative factors and (4) infrastructural implementation. RESULTS: Patients and experts expect the following benefits for telemonitored patients: added safety, early detection of complications, rapid intervention in case of emergency, regular inspection of pump parameters, fewer outpatient clinic visits and the ability to provide more informed feedback and instructions to the family members who take care of the patient. However, the expected acceptance of telemonitoring in left ventricular assist device therapy differed among the interviewed groups. Alongside the aforementioned expected benefits, patients and clinical experts criticised the reduced self-determination for the patient, probable large amounts of time/effort required of the patient and caregiver and data protection/integrity issues (data misuse, device manipulation and mistransfer). Interviewees expected easy handling, proper education and safe data transmission to be necessary factors leading to acceptance. Complication rate reduction, fewer hospitalisations and cost reductions were benefits recorded for the healthcare system and clinics. Clinical experts preferred a telemonitoring centre run by ventricular assist device coordinators. CONCLUSION: Although positive expectations are associated with the use of telemonitoring in left ventricular assist device therapy, further action is needed. For example, software and infrastructure developers will need to address issues such as variations among patients and may need to find a balance between designing individualised solutions for compliant patients and a safe and easy-to-handle set-up. In addition, proper elucidation of users will contribute to the successful implementation of a left ventricular assist device telemonitoring programme among patients and caregivers.


Assuntos
Necessidades e Demandas de Serviços de Saúde , Insuficiência Cardíaca/terapia , Coração Auxiliar , Idoso , Feminino , Grupos Focais , Humanos , Masculino , Pessoa de Meia-Idade , Pesquisa Qualitativa , Telemedicina
3.
J Thorac Dis ; 11(Suppl 6): S853-S863, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31183165

RESUMO

BACKGROUND: Left ventricular assist devices (LVAD) are increasingly used in patients with end stage heart failure. The HeartAssist 5 and aVAD LVADs offer telemetric monitoring capabilities. Here we report our initial single centre experience with the largest telemonitoring cohort of LVAD patients. METHODS: Eleven patients (9 males) received a telemonitoring-capable LVAD and were included in our telemonitoring cohort. Waveforms and alarm data were obtained from the telemonitoring system and hospital records were reviewed for clinical data. RESULTS: Mean age at LVAD implantation was 59±5.1 years (mean ± standard deviation). Seven patients had non-ischemic cardiomyopathy and 4 patients had ischemic cardiomyopathy. Median LVEF at implant was 16% (IQR, 15-20%). The total follow-up time was 2,438 patient-days. A total of 6,216 alarm messages were generated in 11 patients. Most common were low flow alarms due to hypovolemia, followed by low flow alarms because of suspected pump thrombosis. One patient died during follow-up, one received a cardiac transplant and one had the LVAD explanted because of pump thrombosis. Pump thrombosis was suspected in 5 patients with 8 episodes of sudden flow decreases and laboratory signs of haemolysis. CONCLUSIONS: Real-time telemonitoring of LVAD pump flow, motor speed and power consumption is a promising tool in the follow-up of LVAD recipients. Trending pump flow over hours or days can assist in the early detection of complications, especially flow reductions due to hypovolemia and LVAD thrombosis. Further studies are warranted to delineate the impact of remote monitoring on patients' prognosis.

4.
Stud Health Technol Inform ; 260: 192-199, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31118337

RESUMO

The steady increase in the number of patients equipped with mechanical heart support implants, such as left ventricular assist devices (LVAD), along with virtually ubiquitous 24/7 internet connectivity coverage is motive to investigate and develop remote patient monitoring. In this study we explore machine learning approaches to infection severity recognition on driveline exit site images. We apply a U-net convolutional neural network (CNN) for driveline tube segmentation, resulting in a Dice score coefficient of 0.95. A classification CNN is trained to predict the membership of one out of three infection classes in photographs. The resulting accuracy of 67% in total is close to the measured expert level performance, which indicates that also for human experts there may not be enough information present in the photographs for accurate assessment. We suggest the inclusion of thermographic image data in order to better resolve mild and severe infections.


Assuntos
Aprendizado Profundo , Coração Auxiliar , Redes Neurais de Computação , Infecções Relacionadas à Prótese , Infecção dos Ferimentos , Coração Auxiliar/efeitos adversos , Humanos , Infecção dos Ferimentos/diagnóstico
5.
Artif Organs ; 42(7): 695-699, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30117586

RESUMO

Literature on driving capacities of ventricular assist device patients is rare and driving restrictions differ from center to center. Currently, no guidelines exist on whether and when left ventricular assist device (LVAD) patients are allowed to begin driving cars after device implantation. In this study, we assess the driving abilities of patients after LVAD implantation. Three hundred and ninety LVAD patients have been surveyed in a worldwide, multicenter study. The single survey followed a multi-method design, including online, phone, and face-to-face interviews. Out of 390 patients, 72% are still driving and 28% did not continue driving after LVAD implantation. Reasons for discontinuation were capability (24%), insecurity (17%), and disapproval by family members (9%) or doctors (5%). Ninety percent of the patients describe their ability to drive as perfect or adequate. Sixty-nine percent state that they are not restricted in their general driving capacity. Forty-nine percent report not to be restricted in agility to drive by the device equipment. The majority of patients have not been involved in car accidents or major complications (94%). Eight accidents were reported (3%). Out of those, all were minor collisions. No patient reported the occurrence of a fatal accident or casualties. LVAD alarms did occur in six incidents (2%) with the majority being low battery alarms. The results of this study suggest that driving with a left ventricular assist device is safe for stable patients and driving can be resumed 3 months after LVAD implantation after careful patient assessment.


Assuntos
Condução de Veículo , Coração Auxiliar , Implantação de Prótese , Acidentes de Trânsito , Adulto , Idoso , Ventrículos do Coração/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Pessoa de Meia-Idade , Implantação de Prótese/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Adulto Jovem
6.
J Thorac Dis ; 10(Suppl 15): S1696-S1702, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034841

RESUMO

BACKGROUND: Left ventricular assist device (LVAD) (HVAD, Medtronic, Minneapolis, MN, USA) implantation is already a widely accepted treatment option for end-stage heart failure (HF) but also still considered as a rescue therapy for patients suffering from cardiogenic shock. Standard LVAD implantation techniques are often associated with high mortality rates and can result in severe complications, like bleeding or right heart failure (RHF). The aim of our study was to assess the outcome of Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) 1 patients (so called "crash and burn" patients) undergoing a LVAD implantation by standard or less invasive surgery. METHODS: We performed a retrospective evaluation of the 1-year outcome of 32 consecutive HF patients in cardiogenic shock, who underwent LVAD implantation in our institution. A total of 32 INTERMACS 1 patients were emergently operated. Fourteen patients (group A) were operated by using the "Hannover-VAD-technique", which is widely known to be less invasive (upper hemisternotomy and a left-sided anterolateral thoracotomy). In contrast, 18 patients (group B) were implanted with LVAD by using the standard technique (full sternotomy). The primary endpoint was survival after 1 year without device-related re-operations. Secondary endpoints included combined analyses of rates of RHF, respiratory failure and bleeding during the trial period. RESULTS: Baseline characteristics were similar in both groups. Survival after 1 year was higher in group A (69.7% vs. 50.0%). Technique-related adverse events (AEs) were also lower in the minimally invasive group, including a lower RHF (35.7% vs. 61.1%) and of further postoperative bleeding requiring surgery (14.3% vs. 33.3%). CONCLUSIONS: LVAD surgery in INTERMACS 1 patients is associated with remarkably good outcome considering the already very high mortality of those patients, and compared to previously reported surgical outcomes. Our study indicates that minimally invasive LVAD implantation in cardiogenic shock decreases mortality and the incidence of postoperative AEs.

7.
J Thorac Dis ; 10(Suppl 15): S1703-S1710, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034842

RESUMO

BACKGROUND: Driveline infection (DLI) is one of the leading causes for unplanned re-admissions of patients undergoing therapy with left ventricular assist devices (LVAD). In previous studies our group was able to show that a double tunneling implantation technique could significantly reduce infection rates one year after implantation. We now report the results of the five-year-follow up of patients receiving the double tunneling technique. METHODS: We retrospectively analyzed patients receiving LVAD therapy with the HeartWare ventricular assist device (HVAD) (Medtronic, Minnesota, MN, USA) LVAD. For 36 patients (group 1) the driveline was tunneled via a conventional technique. In the remaining 33 patients (group 2) the drivelines were implanted by means of a double tunneling technique. The double tunnel driveline technique involved placement of the driveline in the sheath of the rectus muscle in the umbilical direction and then subcutaneously to the left (alternatively right) upper quadrant. We retrospectively compared both groups. Primary outcome parameters were infection rate and mortality. RESULTS: Five years after LVAD implantation the DLI rate of patients operated by a double tunneling technique was significantly lower than in the conventional technique group [61% (n=22) group 1 vs. 30% (n=10) group 2, P=0.004]. The 5-year mortality was lower in group 2 [42% (n=15) group 1 vs. 27% (n=9) group 2] but did not achieve statistical significance (P=0.10). The days of LVAD support between the two groups were comparable (1,275.56±885.89 group 1 vs. 1,321.94±711.37 group 2). The tunnel technique itself showed to be strongly associated with the occurrence of DLI. Other elevated variables are liver disease and dilated cardiomyopathy as primary disease. CONCLUSIONS: Double tunneling technique for driveline implantation leads to significantly lowered infection rates after 5 years of LVAD therapy and it is associated with a lower mortality.

8.
J Thorac Dis ; 10(Suppl 15): S1711-S1719, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034843

RESUMO

BACKGROUND: Pump thrombosis (PT) is still one of the major adverse events in patients supported with left ventricular assist devices. Nowadays, thrombus detection relies on clinical parameters like reoccurring heart failure symptoms, on changes in pump power consumption, and on laboratory parameters such as increased LDH and hemolysis. Once detected PT is most often persistent and refractory to medical therapy. We therefore designed a novel, non-invasive acoustic method for early pump thrombus detection in an in vitro artificial thrombus model. METHODS: The study was performed in vitro using a mock circulation loop, artificial blood (water-glycerin) and artificial thrombus material (silicon) allowing for repeatable and defined testing. Tested ventricular assist device (VAD) type was HVAD (Medtronic). Three different thrombus locations were evaluated: on the tilted pad of the rotor, in the primary flow path, and in the secondary flow path beneath the rotor. After evaluating baseline parameters (no thrombus, n=20 for each pump), the influence of thrombi of seven different masses (no thrombus, 0.5-5.0 mg) on pump power consumption and acoustic emission of four HVAD devices was investigated via a microphone system (Sennheiser) and subsequent frequency spectrum analysis (n=12). The acoustic analysis algorithm included the number of frequency peaks recorded. RESULTS: Measurements with thrombi on the tilted pad showed an increased number of frequency peaks with all thrombus sizes compared to baseline measurements without any thrombus (baseline: 32.7±7.4; 0.5 mg: 45.3±10.4 up to 5 mg: 80.4±5.5). Power consumption was relevantly elevated in 5mg thrombus measurement only (6.3±1.29 W compared to 4.9±0.14 W at baseline). Measurements with thrombi in the primary and secondary showed no relevant alteration in power consumption and frequency peak count. CONCLUSIONS: We present an acoustic method that detects pump thrombi located on the tilted pad of the HVAD rotor requiring ten times less mass compared to thrombi detected by power consumption alterations used in current detection algorithms. Assuming that pump thrombi are growing over several days, the presented method may detect PT much earlier thereby increasing efficacy of medical therapy and helping to avoid pump exchange.

9.
J Thorac Dis ; 10(Suppl 15): S1728-S1736, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034845

RESUMO

BACKGROUND: Pump thrombosis is the most severe and acute complication of left ventricular assist device (LVAD) therapy and treatment remains challenging. Whilst lysis therapy is often not successful, the exchange of the occluded LVAD is currently the most applied therapeutic treatment for this event. With this study we examine the effects of minimal-invasive LVAD exchange on the rate re-thrombosis and outcomes as well as adverse events in the study group. METHODS: Between February 2004 and December 2015 more than 600 LVADs were implanted at our institution. We retrospectively studied a patient cohort of 41 patients who underwent LVAD exchange because of pump thrombosis at a single institution. Outcomes, rates of re-thrombosis and adverse events were analyzed. RESULTS: Between February 2004 and December 2015, 87 exchanges of LVADs were performed at a single center. In 41 cases pump thrombosis was the reason for LVAD exchange. A total of 28 patient years (10,276 days) were analyzed. Average ICU stay was 15.8±20.4 days and average in-hospital stay 38.1±37.3 days after LVAD exchange. After thirty days the survival rate was 80.5%, 75.6% after 6 months and 70.7% one year after LVAD exchange. Out of the study cohort, three patients have successfully undergone heart transplantation. Twelve patients suffered a stroke postoperatively (29%). Twelve patients needed postoperative dialysis (29%). No technical complications of the VAD were recorded in the study group. Two patients underwent successful LVAD explantation due to myocardial recovery. One year after LVAD exchange, 14 patients underwent re-exchange due to pump thrombosis (34%). Eight patients suffered from a LVAD related infection out of which two patients were treated by pump exchange. A total of 12 patients died during the complete one year follow up of this study (29%). Four patients died in the second, two in the third and one in the fourth year after LVAD exchange. The remaining 17 patients are still ongoing on the device.Conclusions: It is generally feasible to treat pump thrombosis via LVAD exchange. Yet, the exchange procedure is not without risk and the risk of re-thrombosis (34%), stroke (29%), postoperative dialysis (29%) and perioperative complications remains high.

10.
J Thorac Dis ; 10(Suppl 15): S1720-S1727, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034844

RESUMO

BACKGROUND: Device thrombosis is one of the main complications in left ventricular assist devices (LVAD) therapy and remains a challenging issue. Data on device thrombosis management, especially on the application of direct thrombin inhibitors such as argatroban, is limited and a consensus on thrombosis management has not yet been established. METHODS: In this study we analysed retrospective clinical data obtained from 26 patients on VAD therapy who received argatroban for suspected VAD thrombosis, between April, 2012 and February, 2017. RESULTS: Thirteen patients (50%) showed resolution of thrombus after argatroban therapy. Eight of 26 patients (30.8%) were free of thrombotic events 90 days after discharge. Argatroban therapy was unsuccessful in 13 patients of the study cohort, leading to subsequent VAD-exchange. Six of 13 patients with first VAD-exchange had no thrombotic events 90 days after discharge. Six patients (23.1%) suffered from bleeding, especially gastrointestinal bleeding. No hemorrhagic strokes were observed. Three patients (11.5%) did not survive the follow-up period. CONCLUSIONS: Argatroban appears to be an alternative to other pharmacological treatment options in VAD thrombosis. Efficacy and safety characteristics are acceptable, but further investigation on larger populations is necessary.

11.
J Thorac Dis ; 10(Suppl 15): S1737-S1742, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034846

RESUMO

BACKGROUND: End-stage heart failure is associated with severe after-effects such as heart valve insufficiency, cardiac arrhythmias or end-organ dysfunctions. Renal failure or 'cardiorenal syndrome' is a critical end-organ disorder associated with advanced heart failure, which occurs due to low-output failure. Drug therapy or surgical interventions involving left ventricular assist device (LVAD) implantation may impede the progress of heart insufficiency and its after-effects including renal failure. In this study, we investigated the impact of a minimally invasive ventricular assist device implantation through upper hemisternotomy combined with anterolateral thoracotomy on renal function, in patients with perioperative renal failure. METHODS: We analyzed data obtained from 103 patients (80 males, 23 females; mean age 53.8±11.7) who underwent LVAD implantation at our clinic within a 15-year interval (2001-2016) and were dialyzed due to renal dysfunction. 90 patients were operated with the conventional LVAD implantation technique (standard approach surgery, SAS) and 13 underwent less invasive approach implantation (less invasive surgery, LIS). RESULTS: For all patients, data analysis showed significant increase of glomerular filtration rate (GFR) (44.2±56.48 mL/min; 95% CI: 33.81-55.28; P<0.001) along with a significant decrease in the levels of creatinine (-1.08±1.83 mg/dL; 95% CI: 0.75-1.46; P<0.001) and urea (-4.62±13.66 mmol/L; 95% CI: 1.95-7.29; P<0.001). There was a considerable difference in change of renal parameters in patients treated with LIS in comparison to patients who underwent SAS, which was however not statistically significant (GFR: P=0.494; creatinine: P=0.543; urea P=0.918). CONCLUSIONS: LVAD implantation improves kidney function in patients with renal dysfunction. A considerable difference in the change of renal parameters was detected in patients with LIS as compared to SAS, which was not significant possibly due to the limited size of the patient cohort (n=13).

12.
J Thorac Dis ; 10(Suppl 15): S1763-S1768, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034850

RESUMO

BACKGROUND: Functional mitral valve regurgitation is a frequent consequence of left ventricular dysfunction in patients with severe heart failure and is associated with a poor prognosis. It is hypothesized that in this patient group the mitral valve repair, respectively replacement, improves hemodynamics and clinical symptoms. As operative interventions with the help of heart-lung-machine are high risk procedures in these cases, the transcatheter mitral repair with MitraClip® (Abbott Vascular, IL, USA) has recently become frequently used. Most of these cases experience a progress in left ventricular dysfunction, which finally leads to in an implantation of a left ventricular assist device. In this report, we describe a series of six cases in which patients with end stage heart failure and consecutive functional mitral valve regurgitation were supported with a left ventricular assist device after MitraClip implantation. We aimed to investigate, whether the MitraClip implantation leads to an improvement of the hemodynamic prior left ventricular assist device (LVAD)-implantation. METHODS: We retrospectively analyzed the data of 6 patients (5 males, 1 female) with severe heart failure, who underwent LVAD implantation after the MitraClip procedure. The mean age at MitraClip procedure was 64.6 years, mean age at time of LVAD implantation was 65.5 years. The parameters examined were cardiac index (CI), left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDD) and the pulmonary capillary wedge pressure (PCWP). RESULTS: All patients had functional mitral regurgitation (MR). Severity of MR was reduced successfully in all treated patients. All patients were discharged with MR I-II and NYHA functional class III or IV after MitraClip procedure. The mean CI was 2.93 before MitraClip procedure and 2.36 before LVAD-Implantation. Mean LVEDD was 71 mm before MitraClip, mean LVEDD was 70.6 mm before LVAD, and 63.2mm after LVAD implantation respectively. The mean PCWP was 21.5 mmHg before MitraClip and 19.8 mmHg before LVAD implantation respectively. The mean left ventricular ejection fraction (LVEF) was 19.2% before MitraClip, the mean LVEF was 17.6% before LVAD and 15% after LVAD implantation. Two of the LVAD implanted patients died due to post-operative complications. There were no complications after MitraClip procedure. CONCLUSIONS: Our presented patient cohort presented little hemodynamic improvement after the MitraClip procedure. There was no clinical benefit for the patients after MitraClip procedure, progressing left ventricular dysfunction could not be prevented and resulted in subsequent LVAD implantation.

13.
J Thorac Dis ; 10(Suppl 15): S1785-S1789, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034853

RESUMO

Growing worldwide incidences of end-stage heart failure and declining rates of cardiac transplants have given rise to the need for alternative treatment options, based on mechanical circulatory support (MCS) devices such as left ventricular assist devices (LVADs). Technologically advanced LVADs such as the HVAD® (HeartWare®, Medtronic) facilitate safe and efficient treatment of heart failure patients with reduced post-operative complications, which is attributed to their considerably miniaturized size. This also facilitates the development and implementation of novel, minimally-invasive surgical techniques. The HVAD is a centrifugal pump, manufactured by HeartWare Inc., (Framingham, MA, USA) and subsequently by Medtronic Inc., (Minnesota, MN, USA), and has been approved for clinical application after receiving the CE Mark approval in 2008 and the FDA approval in 2012. Current research efforts are focused on further miniaturization alongside optimization of electronic and software controllers as well as implementation of the transcutaneous energy transfer (TET) technology. Salient features of the HVAD pump technology, clinical applications and future optimization strategies have been discussed in this article.

14.
J Thorac Dis ; 10(Suppl 15): S1790-S1793, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034854

RESUMO

Left ventricular assist devices (LVADs) are emerging as the treatment of choice for advanced heart failure due to the dearth of healthy donor hearts for cardiac transplantation. The HeartMate 3 LVAD is a novel centrifugal pump which was developed to provide hemodynamic support in heart failure patients, either as a bridge to transplant (BTT), myocardial recovery, or as destination therapy (DT). Technological and clinical advancements have led to optimized hemocompatibility and development of less invasive surgical procedures for the implantation of this pump. The worldwide first implantation of the HeartMate 3 was performed by Prof. Schmitto and his team at Hannover Medical School, Germany in 2014, paving the way for subsequent surgical developments. This article summarizes the advanced technological and clinical aspects of the HeartMate 3 and outlines future technical developments for safe and effective treatment of advanced heart failure.

15.
J Thorac Dis ; 10(Suppl 15): S1794-S1801, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034855

RESUMO

E-health, especially telemedicine, has undergone a remarkably dynamic development over the past few years. Most experience is currently in the field of telemedical care for heart failure (HF) patients. However, HF patients with an implanted left-ventricular assist device (LVAD) have been more or less excluded from consistent telemonitoring until now. And yet, continual monitoring would be very significant for this patient group because of the complexity of its aftercare, requiring steady control of various parameters (device-related parameters, vital parameters, coagulation parameters, etc.). With timely action, severe and costly complications like pump thromboses and driveline infections could be detected early on or even avoided completely. This paper describes the potential of telemonitoring in LVAD patients, as well as its first clinical implementation according to the available literature. It also describes the requirements for a complete telemonitoring of LVAD patients, facilitating the advancement of this form of continual monitoring to a clinical standard which would increase the quality of aftercare for this very special patient collective enormously.

16.
J Thorac Dis ; 10(Suppl 15): S1825-S1828, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30034859

RESUMO

Although rare, recovery of cardiac function after mechanical support of the left ventricle is the most desirable therapeutic goal in the treatment of end-stage heart failure.Herein, we present a novel implantable device for explantation of the HeartMate 3™ left ventricular assist device (LVAD) in patients, following cardiac recovery, avoiding (re-) sternotomy.This article demonstrates the feasibility of applying this novel device, which fits into the sewing ring of the LVAD.This custom-made mechanical plug offers a promising alternative to standard device-explantation procedures.

19.
Int J Artif Organs ; 41(11): 764-771, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30019601

RESUMO

INTRODUCTION:: Pump thrombosis of left ventricular assist devices remains a devastating complication with high morbidity and mortality. Despite the improvements made, the matter affects many patients and the treatment options are limited to thrombolysis and surgical replacement. An alternative approach using the aspiration Indigo catheter was tested. METHODS:: An Indigo thrombectomy catheter was used within an in vitro model to assess the direct aspiration of prefabricated clots from three different positions within the HeartWare HVAD (inlet, outlet, and housing). The experiments were conducted with a straight and an angled catheter. The aspiration pressure was constant. The flow, power consumption, and pressure head of the left ventricular assist devices were measured at pre-defined measuring points. RESULTS:: The device was more effective (success rate 71%) at inlet and outlet of the left ventricular assist device. In addition, the duration of aspiration and the aspiration volume were shorter in comparison to the aspiration in the housing (inlet M = 19.75 s, outlet M = 60.50 s, and housing M = 38.75 s). Moreover, the aspiration volume was associated with the aspiration duration and the weight of thrombi but not with their volume. Noteworthy, the angled catheter showed an improved performance compared to the straight one (67%-33%). The recorded parameters showed no major changes during the use of the catheter. After application of the Indigo catheter, flow and pressure head of the pump could be restored. CONCLUSIONS:: The aspiration system showed promising results under specific conditions for the treatment of pump thrombosis in an in vitro model. However, further examination, including in vivo experiments, will justify its effectiveness.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Trombose/terapia , Humanos , Trombose/etiologia , Resultado do Tratamento
20.
J Thorac Cardiovasc Surg ; 156(2): 662-669, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29525258

RESUMO

BACKGROUND: The HeartMate 3 (HM3; Abbott Laboratories, Lake Forest, Ill) left ventricular assist device (LVAD) received its Conformité Européenne mark for Europe in October 2015 and is currently under investigation of the Food and Drug Administration to gain approval in the United States. Within this study, we present the first real-world experiences, 1-year outcomes, and adverse events of a single-center cohort treated with the HM3. METHODS: We prospectively studied midterm results of 27 consecutive patients receiving the HM3 at a single institution. After HM 3 implantation, survival, causes of death, and complications were recorded for all patients. Follow up was 100% complete. RESULTS: Twenty-seven patients were enrolled into the study. Within 1 year after HM3 implantation, 3 patients underwent heart transplantation and 3 patients died. Thirty-day survival was 88.9%, 6-month 85.2%, and 1-year survival 85.2%. No pump thrombosis and no strokes were observed within the study group. One incident of gastrointestinal bleeding was observed (3.7%). Right heart failure was diagnosed in 1 patient after HM3 implantation (3.7%). No technical complications of the pump were documented. No pump exchanges were necessary. The main complication was LVAD-related infection (22.2%). CONCLUSIONS: The novel LVAD HM3 has already shown excellent Conformité Européenne mark trial results. Within this cohort, 1-year survival after HM3 implantation was 85%. The HM3 showed excellent midterm results with 0% stroke and 0% pump thrombosis rates 1 year after implantation.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Coração Auxiliar , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Procedimentos Cirúrgicos Cardíacos/mortalidade , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Feminino , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar/efeitos adversos , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Infecções Relacionadas à Prótese , Acidente Vascular Cerebral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...